Features of RMC15A-1
• Small size• Built-in inrush current, overcurrent and overvoltage protection circuits
• V1 isolated from V2 and V3
• Stabilized output voltage (V1, V2, V3)
Ordering Information and Options
RMC(1) 15A(2) - 1(3) - □(4)
(1) Series name(2) Output wattage
(3) Output voltage combination
(4) Optional
C: with Coating
G: Low leakage current
J: Connector type
N: with Cover
Specification
Contents | Specifications | |
---|---|---|
Input Voltage | AC85 - 132V 1Φ or DC110 - 170V | |
Output | Wattage | 16W |
Voltage/Current |
V1 :+5V 2.0A V2 :+12V 0.3A V3 :-12V 0.2A |
|
Adjustable Voltage Range |
5.00 - 5.25V Fixed Fixed |
|
Protection Circuit And Others | Overcurrent Protection | Works over 105% of rating and recovers automatically |
Overvoltage Protection | By zener diode clamping (+5V only) | |
Remote ON/OFF | - | |
Remote Sensing | - | |
Others | - | |
Operating Temperature/Humidity | -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) | |
Safety And Noise Regulations | Agency Approvals (At only AC input) | UL60950-1, C-UL Complies with DEN-AN |
Conducted Noise | Complies with FCC-B, VCCI-B | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 28x80x100mm |
Weight | 250g max (without cover) | |
Cooling Method | Convection | |
Warranty Period | 3-year |
- * For further information and how to use, please see in Cosel product catalog.
Documents Download
Technical Data |
---|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.