| Warranty Period | 5-year (Refer to Instruction Manuals) |
|---|
Features of PDA600F-15
• PBA compatible with the same external dimensions and mounting holes• High efficiency
• Universal input (AC85 - 264V)
• Harmonic attenuator (Complies with IEC61000-3-2)
• Complies with SEMI F47
• Parallel operation and Parallel redundancy operation
• Fan alarm, Remote ON/OFF and other functions
Ordering Information and Options
PD(1) A(2) 600(3) F(4) - □(5)
(2) Single output
(3) Output wattage
(4) Universal input
(5) Output voltage
Recommended EMI Filters
Specification
| Contents | Specifications | |
|---|---|---|
| Input Voltage | 85 - 264VAC 1Φ | |
| Output | Wattage | 645W |
| Voltage/Current | 15V 43A | |
| Adjustable Voltage Range | 10.50 - 16.50V | |
| Protection Circuit And Others | Overcurrent Protection | Works over 105% of rated current or 101% of peak current and recovers automatically |
| Overvoltage Protection | 18.0 - 23.3V | |
| Remote ON/OFF | Provided | |
| Remote Sensing | Provided | |
| Others | - | |
| Operating Temperature/Humidity | -20 to +70℃ (Required Derating), 20 - 90%RH (Non condensing) | |
| Safety And Noise Regulations | Agency Approvals (At only AC input) | UL62368-1, C-UL (CSA62368-1), EN62368-1, Complies with DEN-AN |
| Conducted Noise | Complies with CISPR11-B, CISPR32-B, EN55011-B, EN55032-B, FCC Part 15-B, FCC Part 18-B, VCCI-B | |
| High Attenuation | Complies with IEC61000-3-2 * | |
| Others | Dimensions (WxHxD) | 120x61x190mm [4.72x2.4x7.48 inches] (without terminal block and screw) |
| Weight | 1.6kg max | |
| Cooling Method | Forced cooling (internal fan) | |
| Warranty Period | 5-year (Refer to Instruction Manuals) | |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
| Technical Data | ||
|---|---|---|
| CAD Data | DXF | |
| 3D CAD Data | STEP | |
| IGES | ||
- * For another documents aren't listed, please feel free to contact to a Cosel representative.
Optional Parts
Harness, Terminal Attachment
| Category | Part Number | Description | DXF | |
|---|---|---|---|---|
Harness |
H-PA-3 | Harness for parallel operation. | - | |
| H-SN-20 | Harness for using all functions of CN1 and CN2. | - | ||
| H-SN-21 | Harness for using all functions except remote sensing of CN2. | - | ||
| H-SN-22 | Harness for using all functions of CN3. | - | ||
| H-SN-24 | Harness for using example remote ON/OFF circuit C. | - | ||
Terminal Attachment |
B-MX-1 | Terminal attachment to facilitate terminal connections to power supply output. | - |