Rated Input: AC170 - 264V 3Φ
Rated Output Wattage: 3200W
Slots: 8
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,28V
Rated Output Wattage: 3200W
Slots: 8
Rated Output Voltage: 2V,3.3V,5V,7.5V,12V,15V,18V,24V,28V
Warranty Period | 3-year |
---|
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Features of MAX3200T
• Flexible modular system architecture provides various output configurations• Harmonic attenuator (Complies with IEC61000-3-2) : MAX1600F
• Universal input voltage
• High power factor
• Various functions
• Remote ON/OFF control, alarm, parallel operation
Ordering Information and Options
M1□(1) - □(6) □(7) □(8) □(9) - □□(10) - □□(11)
(1) Abbreviation type name of MAX seriesM3T: MAX3200T
(2) Slot 8 Output module
(3) Slot 7 Output module
(4) Slot 6 Output module
(5) Slot 5 Output module
(6) Slot 4 Output module
(7) Slot 3 Output module
(8) Slot 2 Output module
(9) Slot 1 Output module
(10) Parallel code
(11) Series and option code
Refer to instruction manual
* The number of slot is different depending on the model.
Recommended EMI Filters
Specification
Input Module
Contents | Specifications | |
---|---|---|
Input Voltage | AC170 - 264V 3Φ | |
Output | Number of Slot | 8 |
Total Output power | 3200W | |
Operating Temperature/Humidity | -20 to +65℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE) | |
Safety And Noise Regulations |
Agency Approvals (At only AC input) | UL60950-1, C-UL (CSA60950-1) , EN60950-1, EN50178, Complies with DEN-AN (At only AC input) |
Conducted Noise | Complies with FCC-A, VCCI-A, CISPR22-A and EN55011-A | |
High Attenuation | - | |
Others | Dimensions (WxHxD) | 340x97x300mm [13.39x3.82x11.81 inches] |
Weight | 14kg max | |
Cooling Method | Forced cooling (built-in) | |
Warranty Period | 3-year |
- * For further information and how to use, please see in Cosel product catalog.
Output Module
Contents
Specifications
Module Code | |
---|---|
Number of Slots Used | |
Output | Wattage |
Voltage/Current | |
Adjustable Voltage Range | |
Protection Circuit And Others | Overcurrent Protection |
Overvoltage Protection |
|
Remote ON/OFF |
|
Remote Sensing |
|
Others |
A | B | C | D | E | F | G | H | I |
1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
160W | 264W | 400W | 405W | 408W | 405W | 396W | 408W | 406W |
2V 80A | 3.3V 80A | 5V 80A | 7.5V 54A | 12V 34A | 15V 27A | 18V 22A | 24V 17A | 28V 14.5A |
1.98 - 2.20V | 2.64 - 3.63V | 4.00 - 5.50V | 6.00 - 8.25V | 9.60 - 13.2V | 12.0 - 16.5V | 14.4 - 19.8V | 19.2 - 26.4V | 22.4 - 30.8V |
Works over 105%min of rated current. Automatic recovery. |
||||||||
4.00 - 5.50V | 4.00 - 5.50V | 5.75 - 7.00V | 8.63 - 10.5V | 13.8 - 16.8V | 17.25 - 21.0V | 20.7 - 25.2V | 27.6 - 33.6V | 32.2 - 39.2V |
Available |
||||||||
Available |
||||||||
- |
- * For further information and how to use, please see in Cosel product catalog.
Block Diagram
Documents Download
Here is a technical data.
Please click here to download.
Technical Data |
|
---|---|
CAD Data |
|
- * For another documents aren't listed, please feel free to contact to a Cosel representative.