FCA200F-24

Released 2001

Features of FCA200F-24

• High input voltage (AC187 - 528V)
• Peak load possible
FCA50F, FCA75F (at AC240 - 528V)
FCA200F (at AC323 - 528V)
• Harmonic attenuator (Complies with IEC61000-3-2) (FCA200F)
• DIN rail attachment (Optional)
• Small size

Ordering Information and Options

FCA(1)  200(2)  F(3)  -  24(4)  -  (5)  

(1) Series name
(2) Output wattage
(3) Universal input
(4) Output voltage
(5) Optional
  N1: with DIN rail attachment

Specification

Contents Specifications
Input Voltage AC187 - 528V 1Φ or DC265 - 530V
Output Wattage 200W (Peak 1,008W)
Voltage/Current 24V 8.4A (Peak: 42A)
Adjustable  Voltage Range 21.6 - 26.4V
Protection Circuit And Others Overcurrent Protection Works over 105% of peak current and recovers automatically
Overvoltage Protection Works at 115 - 140% of rating
Remote ON/OFF -
Remote Sensing -
Others -
Operating Temperature/Humidity -10 to +60℃, 20 - 90%RH (Non condensing) (Refer to DERATING CURVE)
Safety And Noise Regulations Agency Approvals (At only AC input) UL60950-1, C-UL EN60950-1
Conducted Noise Complies with FCC-A, CISPR11-A, EN55011-A
High Attenuation -
Others Dimensions (WxHxD) 150x125x125mm
Weight 1,700g max
Cooling Method Convection
Warranty Period 3-year
  • * For further information, please click on the above links.

Documents Download

Technical Data
  • * For another documents aren't listed, please feel free to contact to a Cosel representative.